Skip to main content

Infrared Interpreter

IRIN Incident Position Description

An Infrared Interpreter (IRIN) is responsible for interpreting infrared (IR) imagery from National Infrared Operations (NIROPS) sensors to determine the heat perimeter of fires. They produce GIS-ready files, GIS layers, geo-referenced PDF maps, KMZs, and logs. The IRIN works remotely and often independently but reports to the Situation Unit Leader (SITL). If no SITL is assigned, the IRIN reports to the Plans Section Chief (PSC) for a Type 1, 2, or 3 fire. For a Type 4 fire, the IRIN reports to the Fire Management Officer (FMO) or Assistant Fire Management Officer (AFMO). The IRIN works in the Planning functional area.

Leadership Level 1, Follower (Provide Action)

  • For additional information review Level 1 description, expected behaviors and knowledge, suggested development goals, and self-study opportunities.

Prepare and Mobilize

  • Ensure individual readiness including computer, required software, and user accounts.
  • Gather critical information pertinent to the assignment.
  • Obtain initial briefing from SITL or supervisor, including priority areas, management action points, methods and timing of communications, products, and method of product delivery.
  • Obtain briefing from previous IRIN for incident(s), if possible.

Supervise and Direct Work Assignments

  • Identify, analyze, and use relevant situational information to make informed decisions and take appropriate actions.
  • Adjust actions based on changing information and evolving situation awareness. Develop and implement contingency plans. Communicate changing conditions to flight crew and SITL/supervisor.
  • Ensure incident objectives and performance standards are met within needed timeframes.
  • Manage support to multiple incidents and prioritize accordingly.

Perform Infrared Interpreter-Specific Duties

  • Submit infrared requests to NIROPS per the direction of supervisor.
  • Confirm infrared scan request status and approximate time of scheduled flight and notify incident.
  • Identify and obtain scale-appropriate, background digital data from online or other data sources.
  • Access infrared imagery from current distribution site, secure website, or other.
  • Review infrared imagery for issues, including incomplete file transfer, ortho-rectification, false positives, coverage, and image quality. Report issues to flight crew.
  • Accurately interpret infrared imagery, determine acreage, and create all applicable infrared geospatial data layers.
  • Identify heat perimeter of fire(s), as well as areas of intense, scattered, and isolated heat.
  • Create digital infrared heat map within established guidelines and timeframe, using recommended IR map symbology, depicting all applicable IR geospatial data layers, and conforming to recommended map elements.
  • Deliver all products (GIS layers, geo-referenced PDF maps, KMZs, and logs) to incident via secure website, email, or other means.
  • Utilize recommended file structure and naming convention.
  • When supporting multiple incidents, prioritize work according to values at risk, incident type, fire activity, availability of infrared data, and requested delivery times, unless otherwise directed by National Infrared Coordinator (IRCN).

Communicate and Coordinate

  • Follow established processes and chain of command for downloading, producing, and distributing IR data and products.
  • Maintain direct communication with IRCN and/or flight crew.
  • Prepare for and give morning briefing to SITL or incident supervisor as required by the incident.
  • Advise incident on trade-offs and issues with NIROPS systems versus other infrared systems and products.
  • Advise IRCN of any issues that require follow up during the day.
  • Coordinate an efficient transfer of position duties when mobilizing, demobilizing, or re-assigning to another incident.
  • Conduct and/or participate in After Action Reviews (AAR) if requested.

Manage Risk

  • Monitor for signs and symptoms of fatigue, illness, or injury. Mitigate appropriately.
  • Ensure nighttime access to work location. Inform building manager of work hours. Maintain awareness entering and leaving work location after hours.
  • Ensure access to internet. Plan for alternative internet source in the event of an outage.
  • Change computer and application passwords in a timely manner to ensure completion before work shift and/or to ensure access to Helpdesk if needed.

Document

  • Complete, authorize, ensure timeliness of, and route as required:
  • Upload interpreted infrared maps and digital geospatial data to relevant secure website or other accessible location.
  • Complete interpreter’s daily log for each night’s mission and submit to SITL. Include calculated acreage, imagery issues, and location of heat, especially in relation to management action points or other areas of concern.

Demobilize

  • Coordinate an efficient transfer of position duties.
  • Complete demobilization checkout process before being released from the incident.
  • Upon demobilization, report status to home unit or to local dispatch office.
USWDS Paragraph Bundles

Page Last Modified / Reviewed:
USWDS Paragraph Bundles

 

NWCG Latest Announcements

Updated NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Date: May 10, 2024
Contact: IFUASS Qualification and Curriculum Board (IFUASS) 

The 2024 revision of the NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515 is now available. PMS 515 standardizes the processes and procedures for interagency use of Unmanned Aircraft Systems (UAS), including pilot inspections and approvals. This publication is now available as a PDF for easy use offline.

References:

NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Memorandum 24-003: Removal of Type 1 Command and General Staff (C&G) Incident Position Qualification Pathways

Date: May 10, 2024
Contact: Aitor Bidaburu 

The purpose of this memorandum is to provide NWCG direction for removal of the Type 1 Command and General Staff (C&G) incident position qualification pathways to transition to Complex Incident Management (CIM). Responders may continue to utilize available NWCG pathways to attain Type 1 C&G qualifications until December 31, 2024.

References:

Memorandum 24-003

CIM Story Map

2024 Professional Reading Program

Date: April 26, 2024
Contact: Wildland Fire Leadership Development Program (WFLDP) 

The Wildland Fire Leadership Development Program is announcing the 2024 Professional Reading list! The intent of the Professional Reading Program is to promote the reading and discussion of these books throughout the year. Discussion guides are provided and the corresponding Wildland Fire Leadership Levels have been identified.

The five books chosen for this year are: Young Men and Fire by Norman Maclean, The Wisdom of the Bullfrog by William H. McRaven, The Art of Clear Thinking by Hasard Lee, Emotional Agility by Susan David, and Writing to Persuade by Trish Hall.

References:

Professional Reading Program

Wildland Fire Leadership Levels

NWCG Training Catalog now on Wildland Fire Learning Portal

Date: April 25, 2023
Contact: NWCG Training  

The National Wildfire Coordinating Group (NWCG) has migrated the training catalog from the NWCG website to the Wildland Fire Learning Portal (WFLP) as part of our ongoing efforts to streamline processes and improve efficiency. To facilitate this transition, the training catalog remains available on www.nwcg.gov through April 2024.

Starting May 2024, the training catalog will no longer be accessible on www.nwcg.gov. However, you can still access the complete training catalog by logging in as a guest to the WFLP.

References:

Wildland Fire Learning Portal